MAIN: 410.866.4900 | 365 EMERGENCY SERVICE: 410.866.5201

Image11

Archive

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] State of Maryland Department of Public Safety and Correctional Services [/vc_column_text][vc_empty_space height="4px"][vc_column_text]Baltimore City Youth Detention Center Baltimore, MD Scope of Work J. F. Fischer, Inc. (JFF) performed the mechanical portion of this project consisting of 4 main rooftop Air Handling Units (AHUs) and 35 VRF indoor units for heating and cooling. Additionally, JFF is responsible for the associated outdoor condensing units and ductwork connected to the AHU’s & VRF’s. The domestic water system is being served by 6″ incoming water service along with two 1500-gallon gas fired domestic water heaters, one 2″ mixing valve and two recirculating pumps. The natural gas system consists of a gas booster pump and associated piping serving the domestic water heaters, rooftop AHU’s along with serving the onsite kitchen. 146 security plumbing fixtures and 47 standard plumbing fixtures exist in the building. JFF performed the process by utilizing the commissioning agent’s portal for

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] Baltimore City Public Schools [/vc_column_text][vc_empty_space height="4px"][vc_column_text]HVAC Replacement at Mount Washington Elementary School #221 Baltimore, MD Scope of Work J. F. Fischer, Inc. (JFF) was responsible for the removal of existing classroom unit ventilators, heating air handlers and associated piping work. Two new rooftop air handling units, an air-cooled condensing unit, and an air-cooled chiller replaced this equipment at the three-story school. JFF provided and installed a rooftop acoustic enclosure for the new air-cooled chiller and structural platforms for the rooftop units. JFF also modified the existing structural steel beam support and installed new structural members to accommodate the new rooftop equipment, acoustic enclosure and equipment platforms. In addition, new distribution pumps, piping, and systems were furnished and installed. The heating water supply and return pumping systems to a dual temperature system serving the new heating/cooling unit equipment was upgraded. Also, the existing ATC system was upgraded to

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] Renaissance Baltimore Harborplace Hotel [/vc_column_text][vc_empty_space height="4px"][vc_column_text]Boiler Addition Baltimore, MD Scope of Work J. F. Fischer, Inc. (JFF) converted The Renaissance Hotel from central supply district steam in downtown Baltimore and performed other upgrades. Three hot water heaters and three hot water boilers were furnished and installed. JFF removed and disposed of a 10,000 gallon domestic hot water tank to make room for new equipment while refurbishing and relining two existing 10,000 gallon domestic hot water tanks. JFF furnished and installed new electric steam generators to service kitchen equipment as well as a new Domestic Hot Water mixing valve for room hot water distribution to the entire hotel. JFF also provided new electric distribution and panels to power new equipment. A new gas supply was extended thru the building to new equipment located on the 6th floor as well as extending boiler vents thru exterior wall on 6th

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] Johns Hopkins Health System [/vc_column_text][vc_empty_space height="4px"][vc_column_text]Johns Hopkins Hospital Zayed Bloomberg Adult Emergency Department Modifications Baltimore, MD Scope of Work J. F. Fischer, Inc. (JFF) is contracted to provide Mechanical HVAC and Plumbing services for interior renovations to the Johns Hopkins Hospital, Zayed Bloomberg Adult Emergency Department. This work entails installing mechanical HVAC and Plumbing systems in a currently occupied and operating hospital environment. The HVAC Scope included supplying and installing Air Handling Equipment, and associated ductwork and air distribution systems. The HVAC equipment that was provided and installed includes High Efficiency HEPA Filtration Units, Fan Coil Units, Air Terminal Units, and Blower Coil Units, with associated Heating Water and Chilled Water piping and systems tied into the existing building infrastructure. Included in the Plumbing Scope is providing and installing plumbing fixtures, plumbing specialties, medical gas equipment, medical gas specialties, and associated piping systems. Plumbing Equipment provided and

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] National Aquarium – Animal Care and Research Center [/vc_column_text][vc_empty_space height="4px"][vc_column_text]National Aquarium of Baltimore Baltimore, MD Scope of Work J. F. Fischer, Inc., was contracted to provide Mechanical HVAC, Plumbing, Life Safety Systems and associated specialties for the construction of a new Animal Care and Research facility for the National Aquarium in Baltimore. The scope of work included installing mechanical Life Safety Systems for animal welfare, Mechanical HVAC systems, Plumbing systems, Water Treatment systems, and Automatic Control Systems in a former 2-story manufacturing facility. Life Safety systems include furnishing and installing chilled and heater water systems, plumbing systems and controls, and pressurized air systems for delivery and maintenance of varying sources of fresh water, salt water, filtered water to various animal tanks, aquaria, holding rooms, etc. Included in the HVAC Scope is supplying and installing Air Handling, Humidification/Dehumidification Equipment and controls, chillers, boilers, and associated systems, to serve

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] Verizon [/vc_column_text][vc_empty_space height="4px"][vc_column_text]Annapolis Dial Chiller Replacement Annapolis, MD Scope of Work J. F. Fischer, Inc. replaced four existing unreliable chillers and condensing units with one new modular chiller and four condensing units. The majority of this work was completed in the summer months and involved careful phasing and coordination with Verizon to avoid impacting the chilled water system. Part of the phasing included installing a temporary chiller in a very compact location in historic downtown Annapolis. We will install nearly 2,000 feet of refrigerant piping from the basement up three stories to the rooftop condensers. All of this work will be completed concurrently with a major electrical switchboard replacement project in the building. The scope also includes new pumps, an air separator, a 700-gallon buffer tank, variable frequency drives, and new controls.[/vc_column_text][vc_empty_space height="39px"][/vc_column][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_masonry_media_grid element_width="6" gap="10" grid_id="vc_gid:1636067562968-23cdfeb3-cd37-1" include="8272,8273,8274"][/vc_column][/vc_row]

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] Baltimore County Public Schools [/vc_column_text][vc_empty_space height="4px"][vc_column_text]Installation of Air Conditioning Phase 2 at Dulaney High School Lutherville-Timonium, MD Scope of Work J. F. Fischer, Inc. (JFF) provided air conditioning in many sections of Dulaney High School that were not previously conditioned. Air Conditioning was installed in the cafeteria, gymnasium, auditorium, the tech wing and many classrooms. The school was founded in 1965, making it one of the oldest existing schools in the county. It was enjoyable to see how much the staff and administration appreciated the upgrade. Building Operations worked closely with us and made the project all the more efficient.[/vc_column_text][vc_empty_space height="39px"][/vc_column][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_masonry_media_grid gap="10" grid_id="vc_gid:1636066773684-b8e6cdd4-c43d-4" include="8250,8251,8252,8253,8254,8255,8256,8257,8258,8259,8260,8261,8262,8263,8264,8265"][/vc_column][/vc_row]

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] Exelon – Baltimore Gas & Electric Company [/vc_column_text][vc_empty_space height="4px"][vc_column_text]Notch Cliff Hydronic Line Boiler Replacement Glen Arm, MD Scope of Work BGE’s Notch Cliff Propane/Air Plant serves as a peak-shaving gas production facility that stores liquid propane in an underground cavern. This liquid propane is stored under a variable water cap in a gallon underground granite cavern, pumped out, vaporized and then blended with compressed air to form a mixture, which is interchangeable with natural gas. This mixture is then blended with the natural gas flowing through an adjacent pipeline, and the increased volume of product in the pipeline goes on to serve the Baltimore area on days of peak demand. The Hydronic Boiler upgrade project was created to address various zones of the facility where specific items cannot be subjected to lower temperatures. This upgrade allows the unit to run at a much more efficient rate using scavenged propane

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] Caesars Entertainment [/vc_column_text][vc_empty_space height="4px"][vc_column_text]Horseshoe Casino Baltimore, MD Scope of Work The $442 million-dollar Horseshoe Casino was constructed by Whiting-Turner for Caesars Entertainment in downtown Baltimore. J. F. Fischer, Inc., as a subcontractor to Whiting-Turner, installed the plumbing and HVAC systems. The new high-end three-story casino offers 340,000 square feet of floor space with 9 restaurants and 5 independent bar areas. In addition to the casino, the project consisted of a 16,000 square foot Central Utility Plant housing; (3) 1000-ton water chillers, (3) 1000-ton cooling towers, (9) system water pumps moving 17,800 GPM of conditioned water, and (4) heating boilers generating 16 million BTU’s of heating. Additionally, there are (25) water source heat pumps, (78) fan coil units, (22) rooftop AHU’s, (6) 12-ton CRAC units, (37) exhaust fans exhausting 96,000 CFM of air from the building and (245) terminal boxes located within the casino. The project received a LEED

[vc_row][vc_column offset="vc_col-lg-6 vc_col-md-12"][vc_column_text] Amazon [/vc_column_text][vc_empty_space height="4px"][vc_column_text]Amazon MTN5 Tenant Improvements Baltimore, MD Scope of Work J. F. Fischer, Inc. (JFF) coordinated this project with Hitt Contracting to convert 265,000 square feet of open warehouse space to an Amazon sortation facility where products were received from vendors & sorted out for local delivery. Work included plumbing for new employee bathroom & break area facilities as well as office area bathrooms and a health suite. Domestic water drops throughout the facility for drinking fountains. Compressed air piping was looped throughout the facility to support sortation process equipment. Work also included HVAC work consisting of installation of (10) packaged gas/electric air conditioning rooftop units, installation of (6) HVLS circulation fans, and the installation of an office area split system Air Handling Unit. Installation of natural gas piping was looped throughout the facility, as well as installation of ductwork. The project had an aggressive schedule as